Product Identification
Product ID:PR-1141 PC-60 NAVY BLUE, PART B
MSDS Date:09/12/1990
FSC:8030
NIIN:00N015901
MSDS Number: BYTTL
Responsible Party
GLENDALE, CA 91209
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 818-240-2060
Preparer: RDC
Cage: DO563
Contractor
Telephone: 818-240-2060
Cage: DO563
Ingredients
382 (TESTED PER EPA METHOD 24)
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
LEAST 100 FEET SHOULD SEPARATE THIS OPERATION FROM
RTECS: 9999999ZZ
APPLICATIONS SHOULD BE IN AN AREA SEPARATED FROM
RTECS: 9999999ZZ
PROPERLY DESIGNED & OPERATED I/A/W ACGIH GUIDELINES
RTECS: 9999999ZZ
OTHER APPROPRIATE COLLECTION SYSTEM TO COLLECT ANY
RTECS: 9999999ZZ
AND FULL LENGTH FACESHIELD .
RTECS: 9999999ZZ
PERSONS WORKING IN THE AREA, AND THE GENERAL
RTECS: 9999999ZZ
1.1%.
CAS: 110-43-0
RTECS: MJ5075000
Fraction By Weight: 40%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM
POLYESTER POLYOL POLYMER WITH METHLENE BIS(2- CYCLOHEXYL
CAS: 59330-00-6
Fraction By Weight: 30%
OSHA PEL N/K
ACGIH TLV: N/K
ISOCYANIC ACID, METHYLENEDI-4,1-CYCLOHEXYLENE ESTER;
CAS: 5124-30-1
RTECS: NQ9250000
OSHA PEL 0.01 PPM, C
ACGIH TLV: 0.005 PPM
POLYESTER POLYOL POLYMER WITH ISOPHORONE DIISOCYANATE
CAS: 56336-48-1
Fraction By Weight: 30%
OSHA PEL N/K
ACGIH TLV: N/K
ISOCYANIC ACID, METHYLENE(3,5,5-TRIMETHYL-3,1-
CAS: 4098-71-9
RTECS: NQ9370000
OSHA PEL N/K
ACGIH TLV: 0.005 PPM (MFR)
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: VAPORS WILL CAUSE IRRIT
W/WATERING OF EYES. LIQUID CONTACT WILL CAUSE IRRIT & POSSIBLE
PERMANENT DAMAGE. SKIN: LOCAL SWELLING, SORENESS, ITCHING, IN
SENSITIZED INDIVIDUALS, EXPOS TO LIQUID OR VA PORS WILL RESULT IN
ALLERGIC SKIN RASH.INHAL: IRRIT OF NOSE, THROAT & EYES. BRONCHIAL
IRRIT W/COUGH, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: TIGHTNESS IN CHEST & POSSIBLE
DIFFICULTY BREATHING, MAY PRODUCE ASTHMA-LIKE SYMPS IN SENSITIZED
INDIVIDUALS. INDIVIDUALS SUFFERING FROM ASTHMA OR OTHER CHRONIC
RESPIRATORY CONDITIONS MAY EXH IBIT HEIGHTENED SENSITIVITY TO
ISOCYANATES & SHOULD AVOID INHAL EXPOS. INGEST: IRRIT OF DIGESTIVE
TRACT & STOMACH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH LUKEWARM WATER FOR AT LEAST 15 MINUTES. IF
SYMPTOMS PERSIST, CONSULT MD. SKIN: WASH WITH SOAP AND WATER. IF
SYMPTOMS PERSIST, CONSULT MD. INHALATION: REMOVE TO FRESH AIR. IF
SYMPTOMS ARE PRESENT CONSULT MD. INGESTION: CONSULT MD.
Fire Fighting
Flash Point Method:PMCC
Flash Point:102F,39C
Lower Limits:SEE ING 1
Upper Limits:SEE ING 1
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . USE WATER TO COOL HEAT EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:HIGH TEMPERATURES MAY CAUSE PRESSURE
BUILDUP IN CLOSED CONTAINERS.
Accidental Release
Spill Release Procedures:REMOVE ALL IGNIT SOURCES. WEAR NIOSH/MSHA
APPRVD AIR-SUPPLIED RESP FOR MAJOR UNVENTILATED SPILL. COVER
W/ABSORB MATL, ADD DECONTAM SOLN (5% CONCENTRATED AMMONIA, 2%
DETERGENT, 93% WATER) & ALLOW TO RE ACT FOR 10 MIN. COLLECT IN
CNTNRS, ADD (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:UNPROT PERS MUST BE PVNTD FROM
CONTACTING UNCURED RESIDUE ON EQUIP & AREA SURFS UNTIL PROD HAS
CURED. AVOID MOISTURE CONTAM WHICH WILL CAUSE (SUPDAT)
Other Precautions:WHEN SPRAY APPLYING, USER MUST BE FULLY PROTECTED
FROM CNTCT W/ANY OF MATL. FULL, PERMEATION RESISTANT, PROT SUIT
INCL HEAD COVERING & FACESHIELD, GLOVES & OVERSHOSES IS REQD.
NIOSH/MSHA APPRVD AIR-SU PPLIED RESP MUST BE USED. OTHER (SUPDAT)
Exposure Controls
Respiratory Protection:WHEN APPLYING IN CONFINED AREAS, OR IN OTHER
CIRCUMSTANCES LIKELY TO PRODUCE AIRBORNE LEVELS OF SOLVENT OR
ISOCYANATE IN EXCESS OF PEL, USE A NIOSH/MSHA APPROVED AIR-SUPPLIED
RESPIRATOR.
Ventilation:GENERAL VENTILATION TO MAINTAIN VAPORS BELOW PEL.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 11)
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH FOUNTAIN &
DELUGE SHOWER .
Work Hygienic Practices:DURING SPRAY APPLICATION, STRINGENT PRECS MUST
BE TAKEN TO ENSURE SAFETY OF PERS INVOLVED W/APPLICATION, OTHER
(ING 12)
Supplemental Safety and Health
SPILL PROC: ADDNL DECONTAM SOLN & KEEP LOOSELY COVERED FOR 48 HRS.
HNDLG/STOR PRECS: CO*2 PRESS. DO NOT RESEAL CNTNRS IF MOISTURE
CONTAM IS SUSPECTED. OTHER PRECS: PERS ENTERING AREA FOR ANY REASON
MU ST BE SIMILARLY PROTECTED. SPRAY APPLICATION SHOULD BE ISOLATED
TO REDUCE POTNTL FOR EXPOS. IN OPEN AREAS, AT (ING 7)
Chemical Properties
Vapor Density:SEE ING 1
Spec Gravity:0.97
Evaporation Rate & Reference:SEE ING 1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR VISCOUS LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
WATER, ALCOHOLS, STRONG BASES, AMINES. STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON.
Disposal
Waste Disposal Methods:EPA WASTE NO D-001. DISPOSE OF SPILLAGE IN
COMPLIANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.